Application: | High-performance Transducer, Three Phase Transducer, General Transducer, High Frequency Converter Transducer |
---|---|
Output Type: | Triple |
Principle of Work: | Vector Control Transducer |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Power (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | ||
Motor power (kW) |
0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | ||
Output |
Voltage (V) | Three−phase 0 to rated input voltage | |||||||||||||||
Rated current (A) | 2.5 | 3.8 | 5.5 | 9 | 13 | 17 | 24 | 30 | 39 | 45 | 60 | 75 | 91 | 112 | 150 | ||
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | ||||||||||||||||
Input |
Rated voltage/frequency |
Three−phase 380V/480V; 50Hz/60Hz | |||||||||||||||
Allowable voltage range |
323V ~ 528V; voltage imbalance ≤3%; allowable frequency fluctuation: ±5% | ||||||||||||||||
Rated current (A) | 2.8 | 4.2 | 6.1 | 10 | 15 | 19 | 26 | 33 | 43 | 50 | 66 | 83 | 100 | 123 | 165 | ||
Braking unit | Built−in as standard | Built−in as option | |||||||||||||||
Protection class | IP20 | ||||||||||||||||
Cooling mode | Natural air cooling |
Force air cooling | |||||||||||||||
Power (kW) | 90 | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | |||
Motor power (kW) |
90 | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | |||
Output |
Voltage (V) | Three−phase 0 to rated input voltage | |||||||||||||||
Rated current (A) | 176 | 210 | 253 | 304 | 350 | 380 | 426 | 470 | 520 | 600 | 650 | 690 | 775 | 860 | |||
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | ||||||||||||||||
Input |
Rated voltage/frequency |
Three−phase 380V/480V; 50Hz/60Hz | |||||||||||||||
Allowable voltage range |
323V ~ 528V; voltage imbalance ≤3%; allowable frequency fluctuation: ±5% | ||||||||||||||||
Rated current (A) | 160* | 196* | 232* | 282* | 326* | 352* | 385* | 437* | 491* | 580* | 624* | 670* | 755* | 840* | |||
Braking unit | External braking unit | ||||||||||||||||
Protection class | IP20 | ||||||||||||||||
Cooling mode | Force air cooling |
Type | Terminal | Description | Technical specification |
Terminal RS485 |
RS485+ | Positive end of RS485 | Rate: 4800/9600/19200/38400/57600bps Up to 32 sets of equipment can be paralleled. Relay shall be used if the number exceeds 32 Maximum distance: 500m |
RS485− |
Negative end of RS485 |
||
GND | Ground terminal of RS485 shielding layer |
Internal isolated with COM | |
Operation panel RS485 | CN7 |
RS485 port of operation panel |
The maximum distance between the operation panel and the operation panel interface is 15 meters (standard twisted shielded network cable) |
Digital input |
+24V |
+24V |
24V±10%, internal isolated with GND Maximum output current: 200mA, with overload and short circuit protection |
PLC | Power supply of multi−function input terminal | Short circuited with +24V by default | |
X1 ~ X6 |
Multi−function input terminals 1 ~ 6 |
Input specification: 24VDC,5mA Frequency range: 0 ~ 200Hz Voltage range: 24V±20% |
|
X7/DI |
Multi−function input or pulse input |
Multi−function input: same as X1 ~ X6 ; Pulse input: 0.1kHz ~ 50kHz Voltage range: 24V±20% |
|
COM | Ground terminal for +24V | Internal isolated with GND | |
Digital output |
Y1 | Open collector output | Voltage range: 24V±20%, maximum input current: 50mA |
Y2/DO |
Open collector or pulse output |
Open collector: same as Y1 Pulse output frequency: 0 ~ 50kHz Pulse output voltage range: 24V±20% |
|
COM | Open collector output common end | Internal isolated with GND | |
Analog input |
+10V |
Analog input reference voltage |
10V ±3%, internal isolated with COM Maximum output current: 10mA, with short circuit and overload protection |
AI1 | Analog input channel 1 | 0~20mA: input impedance 500Ω maximum input current: 30mA 0~10V: input impedance 20kΩ maximum input voltage: 15V Resolution: 12 bits (0.025%) 0 ~ 20mA or 0 ~ 10V input can be selected by jumper |
|
AI2 |
Analog input channel 2 |
||
AI3 |
Analog input channel 3 |
−10V ~ 10V: input impedance 20kΩ Resolution: 12 bits (0.025%) Maximum input voltage: ±15V |
|
GND |
Analog ground terminal |
Internal isolated with COM If connects adjustable potentiometer between +10V and GND, the resistance of the potentiometer shall be more than 5kΩ |
|
Analog output |
AO1 | Analog output 1 | 0 ~ 20mA: allowable output impedance 200 ~ 500Ω 0 ~ 10V: allowable output impedance ≥10kΩ Output precision: 2% Resolution: 10 bits (0.1%), with short circuit protection 0 ~ 20mA or 0 ~ 10V output can be selected by jumper |
AO2 |
Analog output 2 |
||
GND | Analog ground terminal | Internal isolated with COM | |
Relay output | RA/RB/RC |
Relay output |
RA−RB: normally closed RA−RC: normally open Contact capacity: 250VAC/1A, 30VDC/1A |