Application: | High-performance Transducer, Three Phase Transducer, General Transducer, High Frequency Converter Transducer |
---|---|
Output Type: | Triple |
Principle of Work: | Vector Control Transducer |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
VA−XX−4TXXG
Power(kW) | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | |
Applicable motor(kW) |
3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | |
Output | Voltage (V) |
Three−phase 0 to rated input voltage | |||||||||||||||
Rated current (A) |
9 |
13 |
17 |
24 |
30 |
39 |
45 |
60 |
75 |
91 |
112 |
150 |
176 |
210 |
253 |
304 |
|
Maximum current (A) |
16 |
23 |
31 |
43 |
54 |
70 |
81 |
108 |
135 |
164 |
202 |
270 |
317 |
378 |
400 |
547 |
|
Overload capacity |
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time characteristics) | ||||||||||||||||
Input | Rated voltage/ frequency |
3-phase 380V~480V 50Hz/60Hz | |||||||||||||||
Allowable voltage range | 323V~528V;Voltage imbalance ≤3%; allowable frequency fluctuation: ±5% |
||||||||||||||||
Rated current (A) |
10 |
15 |
19 |
26 |
33 |
43 |
50 |
66 |
83 |
100 |
123 |
165 |
160* |
196* |
232* |
282* |
|
Braking unit | Built−in as standard | Built−in as option | |||||||||||||||
Protection class | IP20 | ||||||||||||||||
Cooling mode | Self cooled | Air convection cooling |
Control features |
Control mode | Sensorless control | Sensor control |
Starting torque | 0.2% of motor rated speed,180% of rated torque | 0 rpm,180% of rated torque | |
Speed control range | 1:200 |
1:1000 |
|
Speed accuracy | ± 0.5% | ± 0.02% | |
Product functions |
Key functions |
Undervoltage adjustment, flying start, torque limitation, multi-preset speed, motor parameters auto-tuning, flux-weakening control, curremt limitation | |
Speed reference mode | Modbus, keypad, external digital input, analog, simple PLC, PID, pulse input | ||
Dynamic braking |
Braking unit action voltage: 650 ~ 750V; |
||
Dual 485 communication |
Dual 485 communication ports support Modbus protocol (RTU). The standard operation panel can realize remote control box function with a maximum distance of 500m. | ||
Common DC | The full series can realize common DC bus supply for several drives. | ||
Independent duct | The full series adopts independent duct design and supports the installation of heatsink outside the cabinet |
Protection functions |
Power supply undervoltage, overcurrent protection, overvoltage protection, interference protection, abnormal comparison reference input, auto−tuning failure, IGBT protection, heatsink overtemperature protection, overload protection, motor overload protection, peripheral protection, abnormal current detection, output to ground short circuit, abnormal power failure protection, abnormal input power, output phase failure, abnormal EEPROM, abnormal relay contact, temperature sensor taking sample anomaly, encoder disconnection, abnormal +10V power supply, abnormal analog input, motor overtemperature (PTC), abnormal communication, abnormal software version compatibility, abnormal copying, abnormal expansion card connection, terminal mutual exclusion detection failure, hardware overload protection |
|
Efficiency |
At rated power, 7.5kW and below power class ≥93%, 45kW and below power class ≥95%, 55kW and above power class ≥98% | |
Environment |
Operating site |
The product shall be mounted vertically in the electric control cabinet with good ventilation. Horizontal or other installation modes are not allowed. The cooling media is the air. The product shall be installed in the environment free from direct sunlight, dust, corrosive gas, combustible gas, oil mist, steam and drip. |
Ambient temperature | −10 ~ +40ºC, derated at 40 ~ 50ºC, the rated output current shall be decreased by 1% for every temperature rise of 1ºC | |
Humidity | 5~95%, no condensing | |
Altitude | 0 ~ 2000m, derated above 1000m, the rated output current shall be decreased by 1% for every rise of 100m | |
Vibration | 3.5 m/s2,2~9Hz;10 m/s2,9~200Hz;15 m/s2,200~500Hz. | |
Storage temperature | −40~+70ºC. |
Voltage |
Model |
Appearance and Installation Dimension(mm) | approximate weight (kg) |
|||||||
W | H | D | W1 | H1 | D1 | T1 | Hole d | |||
400V |
VA−XX−4T3.7G | 155 |
249 |
197.7 |
136 |
232 |
69 |
8 |
5.5 |
3.3 |
VA−XX−4T5.5G | ||||||||||
VA−XX−4T7.5G | ||||||||||
VA−XX−4T11G | 210 |
337 |
230 |
150 |
324 |
107.5 |
2.5 |
7 |
8.5 |
|
VA−XX−4T15G | ||||||||||
VA−XX−4T18.5G | 285 |
440 |
250 |
200 |
425 |
107.5 |
2.5 |
7 |
17 |
|
VA−XX−4T22G | ||||||||||
VA−XX−4T30G | ||||||||||
VA−XX−4T37G | 315 |
575 |
247 |
220 |
553 |
123.5 |
2.5 |
10 |
25 |
|
VA−XX−4T45G | ||||||||||
VA−XX−4T55G | 400 |
615 |
275 |
270 |
590 |
123.5 |
3.0 |
10 |
35 |
|
VA−XX−4T75G | ||||||||||
VA−XX−4T90G | 465 |
745 |
335 |
343 |
715 |
156 |
3.0 |
12 |
55 |
|
VA−XX−4T110G | ||||||||||
VA−XX−4T132G | 540 |
890 |
395 |
370 |
855 |
205.5 |
4.0 |
14 |
85 |
|
VA−XX−4T160G |