Product Details
Application: High-performance Transducer, Three Phase Transducer, General Transducer, High Frequency Converter Transducer
Output Type: Triple
Principle of Work: Vector Control Transducer
Still deciding? Get samples of US$ 1/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (34)
  • V5-H 185kw Variable Frequency Drive/Inverter/VFD for Wobbulation/Traverse Control Textile Machine
  • V5-H 185kw Variable Frequency Drive/Inverter/VFD for Wobbulation/Traverse Control Textile Machine
  • V5-H 185kw Variable Frequency Drive/Inverter/VFD for Wobbulation/Traverse Control Textile Machine
  • V5-H 185kw Variable Frequency Drive/Inverter/VFD for Wobbulation/Traverse Control Textile Machine
  • V5-H 185kw Variable Frequency Drive/Inverter/VFD for Wobbulation/Traverse Control Textile Machine
  • V5-H 185kw Variable Frequency Drive/Inverter/VFD for Wobbulation/Traverse Control Textile Machine
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Technical Specifications
  • Dimensions
Overview

Basic Info.

Model NO.
V5-H-4T185G/200L
Switch Mode
PWM Control
Main Circuit Type
Voltage
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type, Elevator Special, Textile Special, Constant Torque Universal Type
Brand
V&T
Weight(Kg)
85
Size(mm)
540*890*385(W*H*D)
Braking Unit
Built in as Standard
Cooling Mode
Force Air Cooling
Humidity
5 to 95%, No Condensing
Protection Class
IP20
Transport Package
Wood
Specification
Unit
Trademark
V&T
Origin
China
HS Code
8504409999
Production Capacity
80, 000, 000

Product Description

Product Description

V5-H Series high performance vector control inverter
For over two decades, various industry sectors have been reaping the benefits of V&T's cost-effective, performance-oriented AC Drive solutions. V&T's grasp of specific needs of each industry enables it to offer application-specific solutions for various industries-such as processing ,textile, plastic, ceramic ,pharmaceutical, elevator, oil& gas, power, cement and material-handling.
Main Features
1. Range:0.4 kW to 450kW
2. V/F Sensorless Vector Control, Slip Compensation
3. Staring Torque at 180% at 0.25 Hz for Sensorless Control
4. Component Life Monitor
5. Peer to Peer Communication to share I/Os
6. Built-in PLC logic
7. Multi Keypad
8. Stores last 5 faults
9. Built-in RS485 Modbus RTU Communication
About the Product
V5-H series vector control inverter adds a new dimension to V&T's AC drive solutions. Built to V&T's stringent quality standards, the V5-H is tested and certified to meet global benchmarks, giving you the assurance of total reliability. The V5-H is built to deliver powerful performance. It produces a starting torque of 180% at 0.5Hz, which provides better control at low-speed. Its compact size enables panel-size reduction, hence helps in space-efficient design.
Applications
1. Energy-saving central air conditioning;
2.  Plastic &Textile Machinery;
3. Energy-saving air compressor;          

4. Printing;
5. Fan & Pump / HVAC/AHU/Blowers machine /ID/FD Fan

6. Crane Control;           
7. Food & Packaging Industry;         
8. AHU Control.
 
V5-H 185kw Variable Frequency Drive/Inverter/VFD for Wobbulation/Traverse Control Textile Machine
 
Product Parameters
 
V5−H−4T xxx G Three−phase 400V constant torque/heavy−load application
Power (kW) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Motor
power (kW)
0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75

Output
Voltage (V) Three−phase 0 to rated input voltage
Rated current (A) 2.5 3.8 5.5 9 13 17 24 30 39 45 60 75 91 112 150
Overload capacity 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)


Input
Rated
voltage/frequency
Three−phase 380V/480V; 50Hz/60Hz
Allowable voltage
range
323V ~ 528V; voltage imbalance ≤3%; allowable frequency fluctuation: ±5%
Rated current (A) 2.8 4.2 6.1 10 15 19 26 33 43 50 66 83 100 123 165
Braking unit Built−in as standard Built−in as option
Protection class IP20
Cooling mode Natural air
cooling
Force air cooling
Power (kW) 90 110 132 160 185 200 220 250 280 315 355 400 450 500  
Motor
power (kW)
90 110 132 160 185 200 220 250 280 315 355 400 450 500  


Output
Voltage (V) Three−phase 0 to rated input voltage
Rated current (A) 176 210 253 304 350 380 426 470 520 600 650 690 775 860  
Overload capacity 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)


Input
Rated
voltage/frequency
Three−phase 380V/480V; 50Hz/60Hz
Allowable voltage
range
323V ~ 528V; voltage imbalance ≤3%; allowable frequency fluctuation: ±5%
Rated current (A) 160* 196* 232* 282* 326* 352* 385* 437* 491* 580* 624* 670* 755* 840*  
Braking unit External braking unit
Protection class IP20
Cooling mode Force air cooling

V5−H−4TXXXL       Three−phase 400V  variable torque/light−load application
Power (kW) 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
Motor
power (kW)
1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90

Output
Voltage (V) Three−phase 0 to rated input voltage
Rated current (A) 3.3 5.0 7.5 11 17 22 30 37 44 56 72 91 110 142 176
Overload capacity 115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature)


Input
Rated
voltage/frequency
Three−phase 380V/480V; 50Hz/60Hz
Allowable voltage
fluctuation range
323V ~ 528V; voltage imbalance: ≤3%; allowable frequency fluctuation: ±5%
Rated current (A) 3.6 5.5 8.3 12 19 25 33 40 50 62 80 100 121 156 194
Braking unit Built−in as standard Optional built−in braking unit
Protection class IP20
Cooling mode Natural air
cooling
Forced air cooling
Power (kW) 110 132 160 185 200 220 250 280 315 355 400 450 500 560  
Motor
power (kW)
110 132 160 185 200 220 250 280 315 355 400 450 500 560  

Output
Voltage (V) Three−phase 0 to rated input voltage
Rated current (A) 210 253 304 350 380 426 470 520 600 650 690 775 860 950  
Overload capacity 115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature)

Input
Rated
voltage/frequency
Three−phase 380V/480V; 50Hz/60Hz
Allowable voltage
range
323V ~ 528V; voltage imbalance ≤3%; allowable frequency fluctuation: ±5%
Rated current (A) 196* 232* 282* 326* 352* 385* 437* 491* 580* 624* 670* 755* 840* 920*  
Braking unit External braking unit
Protection class IP20
Cooling mode Forced air cooling

V5−H−2TXXXG       Three−phase 200V  variable torque/heavy−load application
Power (kW) 0.4 0.75 1.5 2.2
Motor
power (kW)
0.4 0.75 1.5 2.2

Output
Voltage (V) Three−phase 0 to rated input voltage
Rated current (A) 3 5 7.5 10
Overload capacity 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse
time lag feature)

Input
Rated
voltage/frequency
Three−phase or single−phase 200V ~ 240V; 50Hz/60Hz
Allowable voltage
range
180V ~ 260V; voltage imbalance ≤3%; allowable frequency fluctuation: ±5%
Rated current (A) 3.8 5.5 8.3 12
Braking unit Built−in as standard
Protection class IP20
Cooling mode Natural air cooling Forced air cooling
 
Technical Specifications
Control characteristics Control mode Vector control 1 Vector control 2 (Without encoder)
Starting torque 0.50Hz 180% 0.25Hz 180%
Range of speed regulation
1:100

1:200
Precision of steady speed
± 0.5%

± 0.2%













Product functions



Key functions
Under-voltage regulation, switchover of run command source(operation panel, terminal and communication), speed tracing function, torque limit, multi− step frequency reference(up to 23 step frequency), motor data identification, S curve acceleration and deceleration, slip compensation, PID regulation, droop control, current limit, switch-over between torque control and speed control, manual torque boost and auto torque boost, programmable digital inputs and programmable digital outputs
Frequency reference mode Parameter setting, operation panel UP/DN, terminal, terminal UP/DN, communication, analog ( AI1/AI2/AI3), pulse DI , etc.

Frequency range
0.00 ~ 300.00Hz
Note:
In the control mode of vector control 1, frequency range from 0.0Hz to 3000.0Hz can be customized according to the customer demand
Start frequency 0.00 ~ 60.00Hz
Acceleration time and deceleration time 0.1 ~ 36000s

Dynamic braking
Braking unit action voltage: 650 ~ 750V; operating time: 100.0s
The braking unit can be built-in for V5−H−4T75G and below equipment


DC braking
DC braking start frequency: 0.00 ~ 300.00Hz
DC braking current: constant torque: 0.0 ~ 120.0%, variable torque: 0.0 ~ 90.0% DC braking time: 0.0 ~ 30.0s; DC braking function does not required waiting time to start to realize quick braking
Magnetic flux braking Enabled or disabled during deceleration are optional, the default setting is enabled









Unique functions

Multi-function M key
The unique multi-function key can be set to frequently used operations: such as JOG, emergency stop, switchover of run command source, switchover of parameters display mode, etc.
Multiple parameters display modes Basic parameters display mode, fast parameters display mode, non−factory setting parameters display mode, last changed 10 parameters display mode

Parameters copy
The standard operation panel can realize the parameters upload, download and display the copy progress. Users can set to forbid overwriting the uploaded parameters
Displayed and hidden parameters group The customer can select to display or hide the parameters group by themselves
Dual 485 communication ports Dual 485 communication ports support maximum distance is 500 meters Modbus protocol (RTU). The
Operation panel Key type or shuttle type operation panel are optional Protection level: IP20 as standard, IP54 as option
Common DC bus All series product support common DC bus
Independent duct All series product adopts independent installation of heat-sink outside the cabinet duct design and supports the
  Universal expansion interface Universal expansion board equipped with CPU for supporting customers secondary development: physical interface SPI bus, software protocol Modbus

Expansion card
Injection molding machine interface card, PG feedback card, air compressor control card, communication adapter card, three phase power supply monitoring card, three phase-sequence detection card, external power
rectifying card
Power-On-Self-Test (POST) Realizing the POST of internal and peripheral circuits, including motor grounded, abnormal +10V power supply output, analog input and disconnection, etc.
Protection function Power supply under-voltage, over-current protection, over-voltage protection, interference protection, abnormal comparison level, motor data identification failure, module(IPM) protection, heat-sink over temperature protection, inverter overload protection, motor overload protection, peripheral protection, abnormal current detection, output short circuit to ground , interruption of power supply when in running status, abnormal input power, output phase loss, abnormal EEPROM protection, abnormal pre-charging contactor detection, temperature sampling disconnection, encoder disconnection, abnormal +10V power supply, abnormal analog input, motor over temperature protection(PTC), abnormal communication, abnormal software version compatibility, abnormal copying, abnormal expansion card connection, terminal mutual exclusion detection, hardware overload protection

Efficiency
At rated power: 7.5kW and below power class ≥93%
45kW and below power class ≥95% 55kW and above power class ≥98%


Environment


Operating site
The product should be mounted vertically in the electric control cabinet with good ventilation. Horizontal or other installation modes are not allowed. The cooling medium is the air. The product should be installed in the environment without dust, corrosive gas, combustible gas, oil mist, steam, drip and free from direct sunlight

Ambient temperature
−10 to +40ºC, the product must be de-rated rated output current for the ambient temperature between 40ºC to 50ºC, the rated output current must be de-rated for 1% per 1ºC temperature rise
Humidity 5 to 95%, no condensing

Altitude
0 to 2000m, the product must be de-rated rated output current for the altitude above 1000 meters, the rated output current must be de-rated for 1% per 100 meters rise
Vibration 3.5m/s2,2 to 9Hz; 10 m/s2,9 to 200Hz; 15 m/s2,200 to 500Hz
Storage temperature −40 to +70ºC
 
Dimensions

V5-H 185kw Variable Frequency Drive/Inverter/VFD for Wobbulation/Traverse Control Textile Machine


Voltage

Model
Outline and mounting dimension (mm) Weight (kg)
W H D W1 H1 D1 T1 Mounting hole diameter


200V
V5−H−2T0.4G

118


190
155

105


173
40.8 3

5.5
1.5
V5−H−2T0.75G 175 60.5 4 2.2
V5−H−2T1.5G 155 40.8 3 1.5
V5−H−2T2.2G 175 60.5 4 2.2
























400V
V5−H−4T0.75G/1.5L 118 190 155 105 173 40.8 3 5.5 1.5
V5−H−4T1.5G/2.2L
118

190

175

105

173

60.5

4

5.5

2.6
V5−H−4T2.2G/3.7L
V5−H−4T3.7G/5.5L
V5−H−4T5.5G/7.5L 155 249 185 136 232 69 8 5.5 4.5
V5−H−4T7.5G/11L
V5−H−4T11G/15L 210 337 200 150 324 107.5 2.5 7 8.5
V5−H−4T15G/18.5L
V5−H−4T18.5G/22L
285

440

220

200

425

107.5

2.5

7

17
V5−H−4T22G/30L
V5−H−4T30G/37L
V5−H−4T37G/45L 315 575 227 220 553 123.5 2.5 10 25
V5−H−4T45G/55L
V5−H−4T55G/75L 400 615 265 270 590 123.5 3.0 10 35
V5−H−4T75G/90L
V5−H−4T90G V5−H−4T110L

465


745


325


343


715


156


3.0


12


55
V5−H−4T110G V5−H−4T132L
V5−H−4T132G
V5−H−4T160L




540




890




385




370




855




205.5




4.0




14




85
V5−H−4T160G V5−H−4T185L
V5−H−4T185G V5−H−4T200L
V5−H−4T200G
V5−H−4T220L
V5−H−4T220G V5−H−4T250L


700



1010



385



520



977



210



4.0



14



125
V5−H−4T250G V5−H−4T280L
V5−H−4T280G
V5−H−4T315L
V5−H−4T315G V5−H−4T355L

810


1358


425


520


1300


210


4.0


14


215
V5−H−4T355G V5−H−4T400L
V5−H−4T400G
V5−H−4T450L



810



1358



425



520



1300



210



4.0



14



215
V5−H−4T450G V5−H−4T500L
V5−H−4T500G V5−H−4T560L



Terminal WiringV5-H 185kw Variable Frequency Drive/Inverter/VFD for Wobbulation/Traverse Control Textile Machine

Functions of Control Circuit Terminals
Type Terminal Description Technical specification


Terminal RS485
RS485+ Positive end of RS485 Rate: 4800/9600/19200/38400/57600bps
Up to 32 sets of equipment can be paralleled. Relay shall be used if the number exceeds 32
Maximum distance: 500m

RS485−

Negative end of RS485
GND Ground terminal of RS485
shielding layer
Internal isolated with COM
Operation panel RS485
CN7

RS485 port of operation panel
The maximum distance between the operation panel and the operation panel interface is 15 meters (standard twisted shielded network cable)





Digital input

+24V

+24V
24V±10%, internal isolated with GND
Maximum output current: 200mA, with overload and short circuit protection
PLC Power supply of multi−function input terminal Short circuited with +24V by default

X1 ~ X6

Multi−function input terminals 1 ~ 6
Input specification: 24VDC,5mA
Frequency range: 0 ~ 200Hz 
Voltage range: 24V±20%

X7/DI

Multi−function input or pulse input
Multi−function input: same as X1 ~ X6 ; Pulse input: 0.1kHz ~ 50kHz
Voltage range: 24V±20%
COM Ground terminal for +24V Internal isolated with GND


Digital output
Y1 Open collector output Voltage range: 24V±20%, maximum input current: 50mA

Y2/DO

Open collector or pulse output
Open collector: same as Y1
Pulse output frequency: 0 ~ 50kHz Pulse output voltage range: 24V±20%
COM Open collector output common end Internal isolated with GND







Analog input

+10V

Analog input reference voltage
10V ±3%, internal isolated with COM
Maximum output current: 10mA, with short circuit and overload protection
AI1 Analog input channel 1 0~20mA: input impedance 500Ω
maximum input current: 30mA 0~10V: input impedance 20kΩ
maximum input voltage: 15V Resolution: 12 bits (0.025%)
0 ~ 20mA or 0 ~ 10V input can be selected by jumper

AI2

Analog input channel 2

AI3

Analog input channel 3
−10V ~ 10V: input impedance 20kΩ
Resolution: 12 bits (0.025%) Maximum input voltage: ±15V

GND

Analog ground terminal
Internal isolated with COM
If connects adjustable potentiometer between +10V and GND, the resistance of the potentiometer shall be
more than 5kΩ


Analog output
AO1 Analog output 1 0 ~ 20mA: allowable output impedance 200 ~ 500Ω 
0 ~ 10V: allowable output impedance ≥10k
Ω 
Output precision: 2%

Resolution: 10 bits (0.1%), with short circuit protection
0 ~ 20mA or 0 ~ 10V output can be selected by jumper

AO2

Analog output 2
GND Analog ground terminal Internal isolated with COM
Relay output
RA/RB/RC

Relay output
RA−RB: normally closed 
RA−RC: normally open

Contact capacity: 250VAC/1A, 30VDC/1A


V5-H 185kw Variable Frequency Drive/Inverter/VFD for Wobbulation/Traverse Control Textile Machine

Product Component Name


V5-H 185kw Variable Frequency Drive/Inverter/VFD for Wobbulation/Traverse Control Textile Machine



Operation Panel Outline and Mounting Dimension

V5-H 185kw Variable Frequency Drive/Inverter/VFD for Wobbulation/Traverse Control Textile Machine

Connection of the Inverter and Peripheral Devices
V5-H 185kw Variable Frequency Drive/Inverter/VFD for Wobbulation/Traverse Control Textile Machine


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier