E5-A Series 110kw Light-Overload Use Universal Frequency Converter

Product Details
Application: High-performance Transducer, Three Phase Transducer, General Transducer, High Frequency Converter Transducer
Output Type: Triple
Principle of Work: V/F Control Transducer
Still deciding? Get samples of US$ 20/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (34)
  • E5-A Series 110kw Light-Overload Use Universal Frequency Converter
  • E5-A Series 110kw Light-Overload Use Universal Frequency Converter
  • E5-A Series 110kw Light-Overload Use Universal Frequency Converter
  • E5-A Series 110kw Light-Overload Use Universal Frequency Converter
  • E5-A Series 110kw Light-Overload Use Universal Frequency Converter
  • E5-A Series 110kw Light-Overload Use Universal Frequency Converter
Find Similar Products
  • Overview
  • Main Features
  • Model Description
  • Nameplate Description
  • Product Outline
  • Technical Specifications
  • Product Component Name
  • Operation Panel
Overview

Basic Info.

Model NO.
E5-A-4T110
Switch Mode
PWM Control
Main Circuit Type
Voltage
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type
Brand
V&T
Dimension(mm)
465*745*325(W*H*D)
Weight(Kg)
55
Protection Class
IP20
Cooling Mode
Forced Air Cooling
Transport Package
Wood
Specification
Unit
Trademark
V&T
Origin
Shenzhen, China
HS Code
8504409999
Production Capacity
80, 000, 000

Product Description

Main Features
1.Power range from 0.4kW to 800kW, Sine wave PWM control;
2. V/F Control ,with slip compensation, current limitation, overvoltage control function, under voltage control function, PID control function, motor parameters static auto-tuning, parameters copy, etc;
3. Containing a variety of fan and water supply energy saving mode and energy saving rate selection;
4. With sleep and wake up function;
5. Overload capacity: 125% of rated current: 1minute;
                                  150% of rated current:6 senonds;
6. Insensitive to motor parameters;               
7. Built-in Modbus RTU communication.
Model Description


E5-A Series 110kw Light-Overload Use Universal Frequency Converter
Nameplate Description

E5-A Series 110kw Light-Overload Use Universal Frequency Converter
 

Product Outline

E5-A Series 110kw Light-Overload Use Universal Frequency Converter


        Three−phase 400V variable torque/light−load application
Power (kW) 15 18.5 22 30 37 45 55 75 90 110 132
Motor
power (kW)
15 18.5 22 30 37 45 55 75 90 110 132
Output Voltage (V) Three−phase 0 to rated input voltage
Rated current (A) 29 35 45 57 70 9T 110 144 180 216 242
Overload capacity 120%    1minute, 10 minutes (inverse time lag feature)

Input
Rated
Voltage/frequency
Threephase 380V/480V; 50Hz/60Hz
Allowable
voltage fluctuation range
323V ~ 528V; voltage imbalance: ≤3%; allowable frequency fluctuation: ±5%
Rated current (A) 32 39 50 62 77 100 121 158 198 238 266
Braking unit Built−in as standard External braking unit
Protection class IP20
Cooling mode Forced air cooling
Power (kW) 160 185 200 220 250 280 315 355 400 450  
Motor
power (kW)
160 185 200 220 250 280 315 355 400 450  

Output
Voltage (V) Three−phase 0 to rated input voltage
Rated current (A) 3T5 365 405 440 495 547 6T0 695 770 866  
Overload
capacity
120%    1 minute, 10 minutes (inverse time lag feature)

Input
Rated voltageTfrequency Threephase 380V/480V; 50Hz/60Hz
Allowable
voltage range
 
323V ~ 528V; voltage imbalance ≤3%; allowable frequency fluctuation: ±5%
Rated
current
(A)
No DC reactor 358 402 446 484 545 600 670 765 845 950  
DC
reactor
282 326 352 385 437 491 580 670 755 840  
Braking unit External braking unit
Protection class IP20
Cooling mode Forced air cooling
Technical Specifications


Control
characteristics
Control mode Enhanced VTF control
Starting torque 0.50Hz    180%
Range of speed regulation 1:100
Precision of steady speed ± 0.5%







Product functions
Key functions Under-voltage regulation, switchover of run command source(operation     panel, terminal and communication), speed tracing function, multi− step    frequency reference(up to 23 step frequency), motor data identification, S curve acceleration and deceleration, slip compensation, PID regulation,     droop control, current limit, manual torque boost and auto torque boost,     programmable digital inputs, programmable digital outputs
Frequency
reference mode
Parameter setting, operation panel UPTDN, terminal, terminal UPTDN, communication, analog AIT, analog AIT,analog AI3, pulse DI, etc.
Frequency range 0.00 ~ 300.00Hz
Start frequency 0.00 ~ 60.00Hz
Acceleration time and deceleration time 0. 1 ~ 36000s
Dynamic braking Braking unit action voltage: 650 ~ 750V; operating time: T00.0s

DC braking
DC braking start frequency: 0.00 ~ 300.00Hz
DC braking current: constant torque: 0.0 ~ 120.0% variable torque: 0.0 ~ 90.0%
DC braking time: 0.0 ~ 30.0s, DC braking function does not required waiting time to start to realize quick braking
Magnetic flux braking Enabled or disabled during deceleration are optional, the default setting is enabled






Unique   functions
Multi-function M key The unique multi-function key can be set to frequently used operations: such as JOG, emergency stop, switchover of run command source, switchover of   parameters display mode, etc.
Multiple parameter display modes Basic parameters display mode, fast parameters display mode, non−factory  setting parameters display mode, last changed T0 parameters display mode
Parameters copy The standard operation panel can realize the parameters upload, download and display the copy progress. Users can set to forbid overwriting the
uploaded parameters
Dual 485
communication ports
Dual 485 communication ports support Modbus protocol (RTU). The maximum distance is 500 meters
Operation panel Key type or shuttle type operation panel are optional Protection level: IP20 as standard, IP54 as option
Common DC bus All series product support common DC bus
Independent duct All series product adopts independent duct design and supports the installation of heat-sink outside the cabinet
Power-On-Self-Test
(POST)
Realizing the POST of internal and peripheral circuits, including motor grounded, abnormal +10V power supply output, analog input and disconnection, etc.


Protection function
Power supply under-voltage, over-current protection, over-voltage protection, interference protection, abnormal comparison level, motor data identification failure, module(IPM) protection, heat-sink over temperature protection, inverter overload protection, motor overload protection, peripheral protection,     abnormal current detection, output short circuit to ground, interruption of power supply when in running   status, abnormal input power, output phase loss, abnormal EEPROM protection, abnormal pre-charging contactor detection, temperature sampling disconnection, abnormal +10V power supply, abnormal analog input, motor over temperature protection(PTC), abnormal communication, abnormal software version compatibility, abnormal copying, terminal mutual exclusion detection, hardware overload protection


Efficiency
At rated power:
E5-H series: 7.5kW and below power class ≥93% 45kW and below power class ≥95%   55kW and above power class ≥98%
E5-A series: 55kW and below power class ≥95% 75kW and above power class ≥98%





Environment

Operating site
The product should be mounted vertically in the electric control cabinet with    good ventilation. Horizontal or other installation modes are not allowed. The  cooling medium is the air. The product should be installed in the environment without dust, corrosive gas, combustible gas, oil mist, steam, drip and free   from direct sunlight

Ambient temperature
10 to +40ºC, the product must bede-rated rated output current for the
ambient temperature between 40ºC to 50ºC, the rated output current must be de-rated for 1% per 1ºC temperature rise
Humidity 5 to 95%, no condensing

Altitude
0 to 2000m, the product must bede-rated rated output current for the altitude above T000 meters, the rated output current must bede-rated for T% per T00 meters rise
Vibration 3.5m/s2,2 to 9Hz; 10 m/s2,9 to 200Hz; 15 m/s2,200 to 500Hz
Storage temperature −40 to +70ºC
 
Product Component Name

 

E5-A Series 110kw Light-Overload Use Universal Frequency Converter
Operation Panel

E5-A Series 110kw Light-Overload Use Universal Frequency Converter





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier