V5-H Series high performance vector control inverter |
Product Description
For over two decades, various industry sectors have been reaping the benefits of V&T's cost-effective, performance-oriented AC Drive solutions. V&T's grasp of specific needs of each industry enables it to offer application-specific solutions for various industries-such as processing ,textile, plastic, ceramic ,pharmaceutical, elevator, oil& gas, power, cement and material-handling.
Main Features
1. Range:0.4 kW to 450kW
2. V/F Sensorless Vector Control, Slip Compensation
3. Staring Torque at 180% at 0.25 Hz for Sensorless Control
4. Component Life Monitor
5. Peer to Peer Communication to share I/Os
6. Built-in PLC logic
7. Multi Keypad
8. Stores last 5 faults
9. Built-in RS485 Modbus RTU Communication
About the Product
V5-H series vector control inverter adds a new dimension to V&T's AC drive solutions. Built to V&T's stringent quality standards, the V5-H is tested and certified to meet global benchmarks, giving you the assurance of total reliability. The V5-H is built to deliver powerful performance. It produces a starting torque of 180% at 0.5Hz, which provides better control at low-speed. Its compact size enables panel-size reduction, hence helps in space-efficient design.
Applications
1. Energy-saving central air conditioning;
2. Plastic &Textile Machinery;
3. Energy-saving air compressor;
4. Printing;
5. Fan & Pump / HVAC/AHU/Blowers machine /ID/FD Fan
6. Crane Control;
7. Food & Packaging Industry;
8. AHU Control.
With complete applications for water supply, with high efficiency, pressure stable, reliable, simple operation, easy installation, small footprint, low noise, no pollution, low investment, effective advantages. Widely used in:
1. Domestic water for buildings, urban areas, business units, public institutions.
2. Waterworks and modern irrigation.
3. The production, domestic water supply, constant pressure water supply, etc.
4. Musical Fountain of automatic water control.
5. Various types of central air-conditioning circulation pump, cooling water supply system.
6. High-rise buildings, hotels, restaurants and other domestic water supply system.
7. Market, office buildings, commercial buildings domestic water supply system.
8. High-rise buildings hot water supply and hot water heating system.
9. Various types of oil constant pressure supply, air constant pressure supply, fan constant pressure control system, etc.
VTDRIVE products range: Frequency inverter, soft starters, servo drives, servo motor PLC, HMI, Servo Motor & Drive system, Frekvensomformer, AC-Umrichter, frequentieregelaars, frekvensomriktare, Frequenzumrichter, AC drives, frequency converters, frequency changers, adjustable speed drives (ASD), adjustable frequency drives (AFD), variable frequency drives (VFD), variable speed drives (VSD), Frequency Invert(AC Drives), Soft Starters, Electrical AC Motor, Induction motor, Brake Units, EMI filter, AC Choke, Brake resistor, Breakers manufacturer in ChinaProducts application: Knitting Machine, compressor, extruding machine, injection machine, motor, braiding machine, pressure fan; Forced draught blower; Blower, blowing machine, blow molding machine, root's blower, film blowing machine, cutter bar, cut-off machine; Slitter, Cutting machine, conveyor, pump, grinder, cluster, glazing machine; Polisher; Polishing machine, laundry-drier, drying machine, ball crusher, ball grinding mill, drawing machine.
Power(KW) |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
75 |
Motor Power(KW) |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
75 |
Output |
Voltage(V) |
Three-phase 0V to rated input voltage |
Rate current(A) |
2.5 |
3.8 |
5.5 |
9 |
13 |
17 |
24 |
30 |
39 |
45 |
60 |
75 |
91 |
112 |
150 |
Overload capacity |
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) |
Input |
Rated voltage/frequency |
Three-phase 380V/480V; 50Hz/60Hz |
Allowable voltage range |
323V ~ 528V; Voltage unbalancedness ≤ 3%; allowable frequency fluctuation: ± 5% |
Rate current(A) |
3.5 |
6.2 |
9.2 |
14.9 |
21.5 |
27.9 |
39 |
50.3 |
60 |
69.3 |
86 |
104 |
124 |
150 |
201 |
Braking unit |
Built-in as standard |
External braking unit needed |
Protection class |
IP20 |
Cooling mode |
Self-cooling |
Forced air convection cooling |
Power(KW) |
90 |
110 |
132 |
160 |
200 |
220 |
280 |
315 |
355 |
400 |
... |
... |
... |
... |
... |
Motor Power(KW) |
90 |
110 |
132 |
160 |
200 |
220 |
280 |
315 |
355 |
400 |
|
|
|
|
|
Output |
Voltage(V) |
Three-phase 0V to rated input voltage |
Rate current(A) |
176 |
210 |
253 |
304 |
377 |
415 |
520 |
585 |
650 |
740 |
|
|
|
|
|
Overload capacity |
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) |
Input |
Rated voltage/frequency |
Three-phase 380V/480V; 50Hz/60Hz |
Allowable voltage range |
323V ~ 528V; Voltage unbalancedness ≤ 3%; allowable frequency fluctuation: ± 5% |
Rate current(A) |
160* |
196* |
232* |
282* |
352* |
385* |
491* |
552* |
624* |
704* |
|
|
|
|
|
Braking unit |
External braking unit needed |
Protection class |
IP20 |
Cooling mode |
Forced air convection cooling |
Power(KW) |
90 |
110 |
132 |
160 |
200 |
220 |
280 |
315 |
355 |
400 |
... |
... |
... |
... |
... |
Motor Power(KW) |
90 |
110 |
132 |
160 |
200 |
220 |
280 |
315 |
355 |
400 |
|
|
|
|
|
Output |
Voltage(V) |
Three-phase 0V to rated input voltage |
Rate current(A) |
176 |
210 |
253 |
304 |
377 |
415 |
520 |
585 |
650 |
740 |
|
|
|
|
|
Overload capacity |
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) |
Input |
Rated voltage/frequency |
Three-phase 380V/480V; 50Hz/60Hz |
Allowable voltage range |
323V ~ 528V; Voltage unbalancedness ≤ 3%; allowable frequency fluctuation: ± 5% |
Rate current(A) |
160* |
196* |
232* |
282* |
352* |
385* |
491* |
552* |
624* |
704* |
|
|
|
|
|
Braking unit |
External braking unit needed |
Protection class |
IP20 |
Cooling mode |
Forced air convection cooling |