V9 Series General purpose Inverter
Δ Multiple System Loop Control Modes
Position loop
Speed loop
Torque loop
Δ Speed Command Selection Is Flexible and Convenient
Modbus communication
Keyboard given
Analog given
Multi-segment speed given
Terminal UP/DN given
Process PID given
Simple PLC speed given
Δ Multiple Running Instructions Setting Methods
Modbus communication
Keyboard given
Terminal given
Δ LED Operation Panel / LCD Liquid Crystal Operation Panel Are Optional
Modbus communication, standard network port connection are adopted in LED operation panel / LCD liquid crystal operation panel
The layout of the button accords with ergonomic principle
One-button parameter entry and exit,easy to operate
Parameter copy function, remote control box function (up to 500m) can be realized by the operation panel
The operation panel has a password lock function to prevent non-professionals from changing parameters by mistake
Δ Upper Computer Communication
Provide 485 communication interface, the communication protocol is Modbus
Parameter upload and download functions can be implemented
Terminal | Symbol | Function description | Technical specifications |
Modbus |
485+ | RS485 positive end | Baud rate: 4800/9600/19200/38400/57600/57600bps Up to 32 units are connected in parallel. If more than 32 units are used, repeaters are required. |
485 - | RS485 negative end | ||
GND | Modbus ground terminal | ||
Keypad | CN7 | RS485 port of keypad | The maximum distance for keypad is 15 m ( network cable) |
Digital inputs |
+24V | +24V | 24V±10%, internal isolated with GND Maximum output current: 200mA |
PLC | Power supply of DI | Short to +24V by default | |
X1 ... X7 | Digital inputs 1 ... 7 | Input specification: 24VDC ± 20%, 5mA Frequency range: 0 … 1KHz |
|
COM | Digital inputs common | The interior isolated from GND | |
Digital outputs | Y1 | Open collector output 1 | Voltage range: 24V±20% Maximum output current: 50mA |
Y2 | Open collector output 2 | ||
COM | Y1 and Y2 common | The interior isolated from GND | |
Relay outputs |
RA/RB/RC |
Relay output 1 |
RA-RB: Normally closed RA-RC: Normally open Contact capacity: 250VAC/1A, 30VDC/1A |
RA1/RC1 (≥11kW) | Relay output 2 | RA1-RC1: Normally open Contact capacity: 250VAC/1A, 30VDC/1A |
|
RA2/RC2 (≥11kW) | Relay output 3 | RA2-RC2: Normally open Contact capacity: 250VAC/1A, 30VDC/1A |
|
Analog inputs |
+10V | AI reference voltage | 10V ±3%, internal isolated with COM Maximum output current: 10mA |
AI1 | Analog input 1 | −10V...10V: Input impedance 20kQ , max. voltage: ±15V 0...20mA: Input impedance 500Q , max. current: 30mA Resolution: 12 bits (0.025%) Note: AI3 input current 0...20mA is not supported. |
|
AI2 | Analog input 2 | ||
AI3 | Analog input 3 | ||
GND | Analog GND | The interior isolated from COM | |
Analog outputs |
AO1 | Analog output 1 | Select analog voltage or current output by jumper 0 ... 20mA: Output allowable impedance 200 to 500 Ω 0 ... 10V: Output allowable impedance ≥10kΩ |
AO2 | Analog output 2 | ||
GND | Analog ground terminal | The interior isolated from COM | |
Resolver (≥11kW) |
1 | REF− | Resolver signal REF1 |
2 | REF+ | Resolver signal REF+ | |
3 | SIN+ | Resolver signal SIN+ | |
4 | SIN− | Resolver signal SIN− | |
5 | COS+ | Resolver signal COS+ | |
6 | PT100 | PT100 temperature sensor | |
7 | COM | PT100 gnd | |
8 | None | ||
9 | COS− | Resolver signal COS− |