After-sales Service: | Yes |
---|---|
Warranty: | 18 Months |
Output Power: | 50kw |
Still deciding? Get samples of US$ 90/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Safe & reliable
Built-in isolation transformer for high load adaptability
Perfect protection function for inverter and battery
Redundancy design for important functions
Abundant configuration
Integrated design, easy to integrate
Support simultaneous access of load,battery,power grid , diesel and PV
Built-in maintenance bypass switch, improve system availability
Intelligent & efficient
Support battery capacity and discharge time prediction
Smooth switching between on and off grid, uninterrupted supply of load
Operate with EMS to monitor system status in real time
Friendly & flexible
Various working modes can be set flexibly
PV controller modular design, easy to expand
Flexible Battery Type(Li-ion,lead-acid)
Model | VTE-30KS-CP | VTE-50KS-CP | VTE-100KS-CP | VTE-150KS-CP | VTE-250KS-CP | VTE-500KS-CP |
AC(on-grid) | ||||||
Max output power(KVA) | 33KVA | 55KVA | 110KVA | 165KVA | 275KVA | 550KVA |
Max output power(KVA) | 30KW | 50KW | 100KW | 150KW | 250KW | 500KW |
Rated voltage(V) | 400V | |||||
Rated current (A) | 43A | 72A | 144A | 216A | 361A | 722A |
Voltage range(V) | 320V-460V | |||||
Rated frequency (HZ) | 50/60HZ | |||||
Frequency range(HZ) | 45-55/55-65HZ | |||||
THDI | <3% | |||||
Power factor | 1lagging~1leading | |||||
AC connection | 3W+N+PE | |||||
Transformer ratio | 100/400 | 200/400 | 270/400 | 270/400 | 270/400 | 315/400 |
AC (off-grid) | |||||||
Max output power(KVA) | 33KVA | 55KVA | 110KVA | 165KVA | 275KVA | 550KVA | |
Rated power(KW) | 30KW | 50KW | 100KW | 150KW | 250KW | 50KW | |
Rated voltage(V) | 400V | ||||||
Rated current(A) | 43A | 72A | 144A | 217A | 361A | 722A | |
THDU | ≤1% linear;or≤5% nonlinear | ||||||
Rated frequency(HZ) | 50/60HZ | ||||||
Overload capacity | 110% long-term |
Photovoltaic input | ||||
Max.PV input voltage(V) | 1000VDC | |||
Max.PV power(KW) | 60/120KW | 120/180/240kw | 300/360KW | 600/660/720KW |
MPPT voltage range(V) | 200VDC-850VDC | |||
MPPT voltage range@full load (V) | 450VDC-850VDC |
Battery | |||||||
Battery voltage range(V) | 250V-850V | 320V-850V | 420V-850V | 420VDC-850VDC | 420VDC-850VDC | 500VDC-850VDC | |
Max. charging power(KW) | 60/120KW | 120/180/240KW | 300/360KW | 600/660/720KW | |||
General data | |||||||
Dimension W*D*H(MM) | 800/800/1900MM | 1200/800/2050MM | (600*720*2050)*1+ 1200*800*2050 | (600*720*2050)*2+ 1600*1050*2050 | |||
Weight(KG) | 620kg/650kg | 720kg/750kg | 1120kg/1150k/1180kg | 1250kg/1280kg/1310KG | 1980kg/2010KG | 3265kg/3295kg/3325kg | |
Operation temperature | .-30ºC to +55ºC | ||||||
Relative humidity | 0~95% non-condensing | ||||||
Ingress protection | IP20 | ||||||
Noise emission(dB) | <70dB | ||||||
Altitude | 5,000m(>3,000Derating) | ||||||
Cooling | Air cooling |
Display and communication | |
Display | LCD touch-screen |
BMS communication | RS485/CAN |
EMS communication | RS485, TCP/IP |
Certificates | EN62109-1/-2, EN62477-1, EN61000-6-2, EN61000-6-4, south Africa N RS097-2-1:2017, pakistan& India IEC61727, IEC62116,/EC 61683 |