Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
---|---|
Output Type: | Triple |
Principle of Work: | Vector Control Transducer |
Still deciding? Get samples of US$ 68/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
V9 Series General purpose Inverter
Δ Multiple System Loop Control Modes
Position loop
Speed loop
Torque loop
Δ Speed Command Selection Is Flexible and Convenient
Modbus communication
Keyboard given
Analog given
Multi-segment speed given
Terminal UP/DN given
Process PID given
Simple PLC speed given
Δ Multiple Running Instructions Setting Methods
Modbus communication
Keyboard given
Terminal given
Δ LED Operation Panel / LCD Liquid Crystal Operation Panel Are Optional
Modbus communication, standard network port connection are adopted in LED operation panel / LCD liquid crystal operation panel
The layout of the button accords with ergonomic principle
One-button parameter entry and exit,easy to operate
Parameter copy function, remote control box function (up to 500m) can be realized by the operation panel
The operation panel has a password lock function to prevent non-professionals from changing parameters by mistake
Δ Upper Computer Communication
Provide 485 communication interface, the communication protocol is Modbus
Parameter upload and download functions can be implemented
Rated Power (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | |
Applicable motor (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | |
Output | Voltage (V) | Three−phase 0 to rated input voltage | ||||||||||||||||
Rated current (A) | 2.5 | 3.8 | 5.5 | 9 | 13 | 17 | 24 | 30 | 39 | 45 | 60 | 75 | 91 | 112 | 150 | 176 | 210 | |
Overload capability | 150% for 60s, 180% for 10s, 200% for 0.5s, interval: 10 minutes (Inverse time characteristic) | |||||||||||||||||
Input | Voltage / frequency | Three−phase 380V/480V; 50Hz/60Hz | ||||||||||||||||
Allowable voltage | 323V ... 528V; voltage imbalance ≤3%; allowable frequency fluctuation: ±5% | |||||||||||||||||
Rated current (A) | 2.8 | 4.2 | 6.1 | 10 | 15 | 19 | 26 | 33 | 43 | 50 | 66 | 83 | 100 | 123 | 165 | 194 | 231 | |
DC reactor | No built−in | Built−in as option | ||||||||||||||||
Brake chopper | Built−in as standard | Built−in as option | ||||||||||||||||
Protection level | IP20 | |||||||||||||||||
Cooling mode | Self cooling | Force air cooling |
Rated Power (kW) | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | 630 | |
Applicable motor (kW) | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | 630 | |
Output | Voltage (V) | Three−phase 0 to rated input voltage | |||||||||||||
Rated current (A) | 253 | 304 | 350 | 380 | 426 | 470 | 520 | 600 | 650 | 690 | 775 | 860 | 950 | 1100 | |
Overload capability | 150% for 60s, 180% for 10s, 200% for 0.5s, interval: 10 minutes (Inverse time characteristic) | ||||||||||||||
Input | Voltage / frequency | Three−phase 380V/480V; 50Hz/60Hz | |||||||||||||
Allowable voltage | 323V ... 528V; voltage imbalance ≤3%; allowable frequency fluctuation: ±5% | ||||||||||||||
Rated current (A) | 232 | 282 | 326 | 352 | 385 | 437 | 491 | 580 | 624 | 670 | 755 | 840 | 920 | 1050 | |
DC reactor |
Built−in as standard |
External as standard |
Built−in AC input reactor as standard | ||||||||||||
Brake chopper | External | ||||||||||||||
Protection level | IP20 | ||||||||||||||
Cooling mode | Force air cooling |
Rated Power (kW) | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 | |
Applicable motor (kW) | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 | |
Output | Voltage (V) | Three−phase 0 to rated input voltage | ||||||||||||||||
Rated current (A) | 3.3 | 5.0 | 7.5 | 11 | 17 | 22 | 29 | 35 | 45 | 57 | 70 | 91 | 110 | 144 | 180 | 216 | 242 | |
Overload capability | 150% for 60s, 180% for 10s, 200% for 0.5s, interval: 10 minutes (Inverse time characteristic) | |||||||||||||||||
Input | Voltage / frequency | Three−phase 380V/480V; 50Hz/60Hz | ||||||||||||||||
Allowable voltage | 323V ... 528V; voltage imbalance ≤3%; allowable frequency fluctuation: ±5% | |||||||||||||||||
Rated current (A) | 3.6 | 5.5 | 8.3 | 12 | 19 | 25 | 32 | 39 | 50 | 61 | 77 | 100 | 121 | 158 | 198 | 238 | 266 | |
DC reactor | No built−in | Built−in as option | ||||||||||||||||
Brake chopper | Built−in as standard | Built−in as option | ||||||||||||||||
Protection level | IP20 | |||||||||||||||||
Cooling mode | Self cooling | Force air cooling |
Rated Power (kW) | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | 630 | 710 | |
Applicable motor (kW) | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | 630 | 710 | |
Output | Voltage (V) | Three−phase 0 to rated input voltage | |||||||||||||
Rated current (A) | 325 | 365 | 405 | 440 | 495 | 547 | 610 | 695 | 770 | 866 | 950 | 1100 | 1200 | 1300 | |
Overload capability | 150% for 60s, 180% for 10s, 200% for 0.5s, interval: 10 minutes (Inverse time characteristic) | ||||||||||||||
Input | Voltage / frequency | Three−phase 380V/480V; 50Hz/60Hz | |||||||||||||
Allowable voltage | 323V ... 528V; voltage imbalance ≤3%; allowable frequency fluctuation: ±5% | ||||||||||||||
Rated current (A) | 282 | 326 | 352 | 385 | 437 | 491 | 580 | 670 | 755 | 840 | 920 | 1050 | 1150 | 1250 | |
DC reactor |
Built−in as standard |
External as standard |
Built−in AC input reactor as standard | ||||||||||||
Brake chopper | External | ||||||||||||||
Protection level | IP20 | ||||||||||||||
Cooling mode | Force air cooling |
Control characteristics |
Control mode | Sensor less vector control | Sensor vector control |
Applicable motor type | Synchronous motor, asynchronous motor | ||
Maximum speed | 600Hz, Note: Higher frequency products are customizable. | ||
Starting torque |
|
200% of rated torque at 0 speed |
|
Speed regulation range | 1:200 | 1:5000 | |
Steady speed precision | ± 0.5% | ± 0.02% | |
Torque control | Y | Y | |
Torque control precision | ±5% | ±3% | |
Torque response time | <20ms | <10ms | |
Positioning control | N | Y | |
Positioning precision | N | ±1 pulse | |
Product function |
Key function |
Speed loop, torque loop, position loop, orientation control, current limit, torque limit, motor auto tune, inertia auto tune, deep flux−weakening control, over − voltage control, under − voltage control, motor flying start, droop control, oscillation suppression, random carrier frequency, master follower control, etc. | |
Speed reference source |
Modbus communication, keypad, external digital input, analog input AI1/AI2/AI3, pulse input, simple PLC, PID, CAN/CANopen, PROFIBUS−DP, PROFINET, etc. | ||
Dynamic brake |
Brake chopper action voltage: 650 ... 750V. The brake chopper of products 0.75kW to 110kW can be built−in:
|
||
Communication |
Built − in Modbus − RTU communication, the maximum distance up to 500 meters. | ||
Keypad |
LED keypad and LCD keypad are available. The keypad can be used as remote−control box by a net cable. |
||
Common DC bus | Full series product support common DC bus directly. | ||
Independent air duct | All series product adopts independent duct design. |
Protection |
Power supply under−voltage, over−current protection, over−voltage protection, auto−tune fault, module protection, heat−sink over-temperature protection, drive overload protection, motor overload protection, peripheral protection, current abnormal detection, output short − circuit to ground protection, EEPROM abnormal detection, temperature sampling disconnection, encoder disconnection, analog input abnormal detection, motor over-temperature, communication fault, hardware overload protection, etc. | |
Efficiency |
At rating condition:
|
|
Environment |
Operating site |
|
Ambient temperature |
|
|
Humidity | 5 ... 95%, no condensation is allowed. | |
Altitude |
|
|
Vibration |
|
|
Storage temperature | −40 ... +70ºC. |
Terminal | Symbol | Function description | Technical specifications |
Modbus |
485+ | RS485 positive end | Baud rate: 4800/9600/19200/38400/57600/57600bps Up to 32 units are connected in parallel. If more than 32 units are used, repeaters are required. |
485 - | RS485 negative end | ||
GND | Modbus ground terminal | ||
Keypad | CN7 | RS485 port of keypad | The maximum distance for keypad is 15 m ( network cable) |
Digital inputs |
+24V | +24V | 24V±10%, internal isolated with GND Maximum output current: 200mA |
PLC | Power supply of DI | Short to +24V by default | |
X1 ... X7 | Digital inputs 1 ... 7 | Input specification: 24VDC ± 20%, 5mA Frequency range: 0 … 1KHz |
|
COM | Digital inputs common | The interior isolated from GND | |
Digital outputs | Y1 | Open collector output 1 | Voltage range: 24V±20% Maximum output current: 50mA |
Y2 | Open collector output 2 | ||
COM | Y1 and Y2 common | The interior isolated from GND | |
Relay outputs |
RA/RB/RC |
Relay output 1 |
RA-RB: Normally closed RA-RC: Normally open Contact capacity: 250VAC/1A, 30VDC/1A |
RA1/RC1 (≥11kW) | Relay output 2 | RA1-RC1: Normally open Contact capacity: 250VAC/1A, 30VDC/1A |
|
RA2/RC2 (≥11kW) | Relay output 3 | RA2-RC2: Normally open Contact capacity: 250VAC/1A, 30VDC/1A |
|
Analog inputs |
+10V | AI reference voltage | 10V ±3%, internal isolated with COM Maximum output current: 10mA |
AI1 | Analog input 1 | −10V...10V: Input impedance 20kQ , max. voltage: ±15V 0...20mA: Input impedance 500Q , max. current: 30mA Resolution: 12 bits (0.025%) Note: AI3 input current 0...20mA is not supported. |
|
AI2 | Analog input 2 | ||
AI3 | Analog input 3 | ||
GND | Analog GND | The interior isolated from COM | |
Analog outputs |
AO1 | Analog output 1 | Select analog voltage or current output by jumper 0 ... 20mA: Output allowable impedance 200 to 500 Ω 0 ... 10V: Output allowable impedance ≥10kΩ |
AO2 | Analog output 2 | ||
GND | Analog ground terminal | The interior isolated from COM | |
Resolver (≥11kW) |
1 | REF− | Resolver signal REF1 |
2 | REF+ | Resolver signal REF+ | |
3 | SIN+ | Resolver signal SIN+ | |
4 | SIN− | Resolver signal SIN− | |
5 | COS+ | Resolver signal COS+ | |
6 | PT100 | PT100 temperature sensor | |
7 | COM | PT100 gnd | |
8 | None | ||
9 | COS− | Resolver signal COS− |
Voltage |
Model |
Outline and mounting dimensions (mm) | Weight (kg) |
||||||
W |
H |
D |
W1 |
H1 |
T1 |
Mounting hole diameter d |
|||
400V |
V9−H−4T0.75G/1.5L | 118 | 190 | 155 | 105 | 173 | 3 | 5.5 | 1.5 |
V9−H−4T1.5G/2.2L | 118 |
190 |
175 |
105 |
173 |
4 |
5.5 |
2.6 |
|
V9−H−4T2.2G/3.7L | |||||||||
V9−H−4T3.7G/5.5L | |||||||||
V9−H−4T5.5G/7.5L | 155 | 249 | 185 | 136 | 232 | 8 | 5.5 | 3 | |
V9−H−4T7.5G/11L | |||||||||
V9−H−4T11G/15L | 198 | 299 | 190 | 160 | 283 | 1.2 | 6 | 8 | |
V9−H−4T15G/18.5L | |||||||||
V9−H−4T18.5G/22L | 223 | 348 | 208 | 195 | 335 | 1.5 | 6 | 10 | |
V9−H−4T22G/30L | |||||||||
V9−H−4T30G/37L | 264 | 430 | 235 | 230 | 418 | 1.5 | 7 | 18 | |
V9−H−4T37G/45L | |||||||||
V9−H−4T45G/55L | 305 | 545 | 270 | 245 | 523 | 1.5 | 10 | 35 | |
V9−H−4T55G/75L | |||||||||
V9−H−4T75G/90L | 338 |
580 |
310 |
270 |
560 |
1.5 |
10 |
52 |
|
V9−H−4T90G/110L | |||||||||
V9−H−4T110G/132L | |||||||||
V9−H−4T132G/160L | 400 | 917 | 323 | 320 | 890 | 3.0 | 12 | 75 | |
V9−H−4T160G/185L | |||||||||
V9−H−4T185G/200L | 540 | 890 | 385 | 370 | 855 | 4.0 | 14 | 85 | |
V9−H−4T200G/220L | |||||||||
V9−H−4T220G/250L | 540 | 890 | 416 | 370 | 855 | 4.0 | 14 | 85 | |
V9−H−4T250G/280L | 700 | 1010 | 385 | 520 | 977 | 4.0 | 14 | 125 | |
V9−H−4T280G/315L | |||||||||
V9−H−4T315G/355L | 700 | 1010 | 418.5 | 520 | 977 | 4.0 | 14 | 125 | |
V9−H−4T355G/400L | 810 | 1358 | 425 | 520 | 1300 | 4.0 | 14 | 215 | |
V9−H−4T400G/450L | 810 |
1358 |
425 |
520 |
1300 |
4.0 |
14 |
215 |
|
V9−H−4T450G/500L | |||||||||
V9−H−4T500G/560L |