• V&T E5-H Universal Use Vector Control VFD/VSD/AC Drive for Fan & Pump Application 0.4 to 2.2kw - HD
  • V&T E5-H Universal Use Vector Control VFD/VSD/AC Drive for Fan & Pump Application 0.4 to 2.2kw - HD
  • V&T E5-H Universal Use Vector Control VFD/VSD/AC Drive for Fan & Pump Application 0.4 to 2.2kw - HD
  • V&T E5-H Universal Use Vector Control VFD/VSD/AC Drive for Fan & Pump Application 0.4 to 2.2kw - HD
  • V&T E5-H Universal Use Vector Control VFD/VSD/AC Drive for Fan & Pump Application 0.4 to 2.2kw - HD
  • V&T E5-H Universal Use Vector Control VFD/VSD/AC Drive for Fan & Pump Application 0.4 to 2.2kw - HD

V&T E5-H Universal Use Vector Control VFD/VSD/AC Drive for Fan & Pump Application 0.4 to 2.2kw - HD

Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Principle of Work: V/F Control Transducer
Voltage of Power Supply: Low Voltage Variable-Frequency Drive
Link of Transformation: AC-DC-AC Variable-Frequency Drive
Trademark: V&T
Samples:
US$ 50/Piece 1 Piece(Min.Order)
| Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Guangdong, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (34)
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
V&T E5-H
Origin
Shenzhen
HS Code
8850440990
Production Capacity
100, 000, 000

Product Description

V&T E5-H Universal Use Vector Control VFD/VSD/AC Drive for Fan & Pump Application 0.4 to 2.2kw - HD
Product Description

1. Variable Speed Drive Motor Control
2. Excellent torque control and reliable brake control frequency inverter
3. Approved by ECMG, CE, ABS, TUV, ISO9000
4. Global qualified frequency inverter supplier

 5. Top 10 Chinese Inverter suppier from 2010-2017


With complete applications for water supply, with high efficiency, pressure stable, reliable, simple operation, easy installation, small footprint, low noise, no pollution, low investment, effective advantages. Widely used in:
1. Domestic water for buildings, urban areas, business units, public institutions.
2. Waterworks and modern irrigation.
3. The production, domestic water supply, constant pressure water supply, etc.
4. Musical Fountain of automatic water control.
5. Various types of central air-conditioning circulation pump, cooling water supply system.
6. High-rise buildings, hotels, restaurants and other domestic water supply system.
7. Market, office buildings, commercial buildings domestic water supply system.
8. High-rise buildings hot water supply and hot water heating system.
9. Various types of oil constant pressure supply, air constant pressure supply, fan constant pressure control system, etc.
 

V&T products range: Frequency inverter, soft starters, servo drives, servo motor PLC, HMI, Servo Motor & Drive system, Frekvensomformer, AC-Umrichter, frequentieregelaars, frekvensomriktare, Frequenzumrichter, AC drives, frequency converters, frequency changers, adjustable speed drives (ASD), adjustable frequency drives (AFD), variable frequency drives (VFD), variable speed drives (VSD), Frequency Invert(AC Drives), Soft Starters, Electrical AC Motor, Induction motor, Brake Units, EMI filter, AC Choke, Brake resistor, Breakers manufacturer in ChinaProducts application: Knitting Machine, compressor, extruding machine, injection machine, motor, braiding machine, pressure fan; Forced draught blower; Blower, blowing machine, blow molding machine, root's blower, film blowing machine, cutter bar, cut-off machine; Slitter, Cutting machine, conveyor, pump, grinder, cluster, glazing machine; Polisher; Polishing machine, laundry-drier, drying machine, ball crusher, ball grinding mill, drawing machine.

Power(KW) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Motor Power(KW) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Output Voltage(V) Three-phase 0V to rated input voltage
Rate current(A) 2.5 3.8 5.5 9 13 17 24 30 39 45 60 75 91 112 150
Overload capacity 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)
Input Rated voltage/frequency Three-phase 380V/480V; 50Hz/60Hz
Allowable voltage range 323V ~ 528V; Voltage unbalancedness ≤ 3%; allowable frequency fluctuation: ± 5%
Rate current(A) 3.5 6.2 9.2 14.9 21.5 27.9 39 50.3 60 69.3 86 104 124 150 201
Braking unit Built-in as standard External braking unit needed
Protection class IP20
Cooling mode Self-cooling Forced air convection cooling
Power(KW) 90 110 132 160 200 220 280 315 355 400 ... ... ... ... ...
Motor Power(KW) 90 110 132 160 200 220 280 315 355 400          
Output Voltage(V) Three-phase 0V to rated input voltage
Rate current(A) 176 210 253 304 377 415 520 585 650 740          
Overload capacity 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)
Input Rated voltage/frequency Three-phase 380V/480V; 50Hz/60Hz
Allowable voltage range 323V ~ 528V; Voltage unbalancedness ≤ 3%; allowable frequency fluctuation: ± 5%
Rate current(A) 160* 196* 232* 282* 352* 385* 491* 552* 624* 704*          
Braking unit External braking unit needed
Protection class IP20
Cooling mode Forced air convection cooling
Power(KW) 90 110 132 160 200 220 280 315 355 400 ... ... ... ... ...
Motor Power(KW) 90 110 132 160 200 220 280 315 355 400          
Output Voltage(V) Three-phase 0V to rated input voltage
Rate current(A) 176 210 253 304 377 415 520 585 650 740          
Overload capacity 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)
Input Rated voltage/frequency Three-phase 380V/480V; 50Hz/60Hz
Allowable voltage range 323V ~ 528V; Voltage unbalancedness ≤ 3%; allowable frequency fluctuation: ± 5%
Rate current(A) 160* 196* 232* 282* 352* 385* 491* 552* 624* 704*          
Braking unit External braking unit needed
Protection class IP20
Cooling mode Forced air convection cooling
V&T E5-H Universal Use Vector Control VFD/VSD/AC Drive for Fan & Pump Application 0.4 to 2.2kw - HDV&T E5-H Universal Use Vector Control VFD/VSD/AC Drive for Fan & Pump Application 0.4 to 2.2kw - HDV&T E5-H Universal Use Vector Control VFD/VSD/AC Drive for Fan & Pump Application 0.4 to 2.2kw - HDV&T E5-H Universal Use Vector Control VFD/VSD/AC Drive for Fan & Pump Application 0.4 to 2.2kw - HDV&T E5-H Universal Use Vector Control VFD/VSD/AC Drive for Fan & Pump Application 0.4 to 2.2kw - HDV&T E5-H Universal Use Vector Control VFD/VSD/AC Drive for Fan & Pump Application 0.4 to 2.2kw - HDV&T E5-H Universal Use Vector Control VFD/VSD/AC Drive for Fan & Pump Application 0.4 to 2.2kw - HDV&T E5-H Universal Use Vector Control VFD/VSD/AC Drive for Fan & Pump Application 0.4 to 2.2kw - HD

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now