V9 11kw High Performance Universal Speed AC Drive/VFD/Frequency Inverter

Product Details
Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Principle of Work: Vector Control Transducer
Still deciding? Get samples of US$ 68/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (34)
  • V9 11kw High Performance Universal Speed AC Drive/VFD/Frequency Inverter
  • V9 11kw High Performance Universal Speed AC Drive/VFD/Frequency Inverter
  • V9 11kw High Performance Universal Speed AC Drive/VFD/Frequency Inverter
  • V9 11kw High Performance Universal Speed AC Drive/VFD/Frequency Inverter
  • V9 11kw High Performance Universal Speed AC Drive/VFD/Frequency Inverter
  • V9 11kw High Performance Universal Speed AC Drive/VFD/Frequency Inverter
Find Similar Products
  • Overview
  • About Product
  • Product Description
  • Product Parameters
  • Technical Specifications
  • Terminal Wiring
  • Dimension
Overview

Basic Info.

Model NO.
V9-H-4T11G/15L
Switch Mode
PWM Control
Main Circuit Type
Voltage
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type, Elevator Special, Textile Special, Constant Torque Universal Type
Brand
V&T
Weight(Kg)
8
Dimension(mm)
198*299*190(W*H*D)
Cooling Mode
Force Air Cooling
Power Range
0.75kw-500kw
Adaptable Motor
Asynchonous Motor, Synchronous Motor
Protection Level
IP20
Transport Package
Carton/Wood
Specification
Unit
Trademark
V&T
Origin
850440999
HS Code
850440999

Product Description

V9 Series General purpose Inverter

Easy Control/ Friendly Interface/ Multifunction Operation / Brilliant Succession
About Product

The V9−H Series General Purpose Inverter is a high-performance vector control and torque-controlled inverter. Vector control techniques and torque control techniques are employed. The V9−H product voltage range 220V and 380V, Power range 0.75Kw to 630Kw. It can suit synchronous and asynchronous motor. Synchronous open loop, Synchronous closed loop, Asynchronous V/F, Asynchronous closed loop, Asynchronous vector, these control modes can meet various needs.
 
Representative Industry

Machine tool industry, Lift, Crane industry, Air compressor industry, Papermaking industry, Oilfield, Plastic industry, Metal processing, Municipal engineering, Textile industry, Printing and packaging, Industrial mining, Processing center, Wood processing, Cable Machinery, Food Packaging, Electric Vehicles, Centrifuges and High-end applications ect. 

Fetures

Δ   Multiple System Loop Control Modes

Position loop

Speed loop

Torque loop

Δ  Speed Command Selection Is Flexible and Convenient

Modbus communication

Keyboard given

Analog given

Multi-segment speed given

Terminal UP/DN given

Process PID given

Simple PLC speed given

Δ  Multiple Running Instructions Setting Methods

Modbus communication

Keyboard given

Terminal given

Δ  LED Operation Panel / LCD Liquid Crystal Operation Panel Are Optional

Modbus communication, standard network port connection are adopted in LED operation panel / LCD liquid crystal operation panel

The layout of the button accords with ergonomic principle

One-button parameter entry and exit,easy to operate

Parameter copy function, remote control box function (up to 500m) can be realized by the operation panel

The operation panel has a password lock function to prevent non-professionals from changing parameters by mistake

Δ  Upper Computer Communication

Provide 485 communication interface, the communication protocol is Modbus

Parameter upload and download functions can be implemented
 

Product Description

V9 11kw High Performance Universal Speed AC Drive/VFD/Frequency Inverter
V9 11kw High Performance Universal Speed AC Drive/VFD/Frequency InverterV9 11kw High Performance Universal Speed AC Drive/VFD/Frequency Inverter

Product Parameters
  • V9−H−4TXXXG Three phase 400V constant torque / heavy load application
Rated Power (kW) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110
Applicable motor (kW) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110
Output Voltage (V) Three−phase 0 to rated input voltage
Rated current (A) 2.5 3.8 5.5 9 13 17 24 30 39 45 60 75 91 112 150 176 210
Overload capability 150% for 60s, 180% for 10s, 200% for 0.5s, interval: 10 minutes (Inverse time characteristic)
Input Voltage / frequency Three−phase 380V/480V; 50Hz/60Hz
Allowable voltage 323V ... 528V; voltage imbalance ≤3%; allowable frequency fluctuation: ±5%
Rated current (A) 2.8 4.2 6.1 10 15 19 26 33 43 50 66 83 100 123 165 194 231
DC reactor No built−in Built−in as option
Brake chopper Built−in as standard Built−in as option
Protection level IP20
Cooling mode Self cooling Force air cooling
Rated Power (kW) 132 160 185 200 220 250 280 315 355 400 450 500 560 630
Applicable motor (kW) 132 160 185 200 220 250 280 315 355 400 450 500 560 630
Output Voltage (V) Three−phase 0 to rated input voltage
Rated current (A) 253 304 350 380 426 470 520 600 650 690 775 860 950 1100
Overload capability 150% for 60s, 180% for 10s, 200% for 0.5s, interval: 10 minutes (Inverse time characteristic)
Input Voltage / frequency Three−phase 380V/480V; 50Hz/60Hz
Allowable voltage 323V ... 528V; voltage imbalance ≤3%; allowable frequency fluctuation: ±5%
Rated current (A) 232 282 326 352 385 437 491 580 624 670 755 840 920 1050


DC reactor

Built−in as standard


External as standard
Built−in AC input reactor as standard
Brake chopper External
Protection level IP20
Cooling mode Force air cooling
  • Higher power products are customizable.
  • Products with 220V, 690V and other supply voltage are customizable.

V9−H−4TXXXL Three phase 400V constant torque / Light load application
Rated Power (kW) 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132
Applicable motor (kW) 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132
Output Voltage (V) Three−phase 0 to rated input voltage
Rated current (A) 3.3 5.0 7.5 11 17 22 29 35 45 57 70 91 110 144 180 216 242
Overload capability 150% for 60s, 180% for 10s, 200% for 0.5s, interval: 10 minutes (Inverse time characteristic)
Input Voltage / frequency Three−phase 380V/480V; 50Hz/60Hz
Allowable voltage 323V ... 528V; voltage imbalance ≤3%; allowable frequency fluctuation: ±5%
Rated current (A) 3.6 5.5 8.3 12 19 25 32 39 50 61 77 100 121 158 198 238 266
DC reactor No built−in Built−in as option
Brake chopper Built−in as standard Built−in as option
Protection level IP20
Cooling mode Self cooling Force air cooling
Rated Power (kW) 160 185 200 220 250 280 315 355 400 450 500 560 630 710
Applicable motor (kW) 160 185 200 220 250 280 315 355 400 450 500 560 630 710
Output Voltage (V) Three−phase 0 to rated input voltage
Rated current (A) 325 365 405 440 495 547 610 695 770 866 950 1100 1200 1300
Overload capability 150% for 60s, 180% for 10s, 200% for 0.5s, interval: 10 minutes (Inverse time characteristic)
Input Voltage / frequency Three−phase 380V/480V; 50Hz/60Hz
Allowable voltage 323V ... 528V; voltage imbalance ≤3%; allowable frequency fluctuation: ±5%
Rated current (A) 282 326 352 385 437 491 580 670 755 840 920 1050 1150 1250


DC reactor

Built−in as standard


External as standard
Built−in AC input reactor as standard
Brake chopper External
Protection level IP20
Cooling mode Force air cooling
 
Technical Specifications











Control characteristics
Control mode Sensor less vector control Sensor vector control
Applicable motor type Synchronous motor, asynchronous motor
Maximum speed 600Hz, Note: Higher frequency products are customizable.


Starting torque
  • Asynchronous motor: 200% of rated torque at 0.25Hz.
  • Synchronous motor: 150% of rated
torque at 1.5% of rated speed


200% of rated torque at 0 speed
Speed regulation range 1:200 1:5000
Steady speed precision ± 0.5% ± 0.02%
Torque control Y Y
Torque control precision ±5% ±3%
Torque response time <20ms <10ms
Positioning control N Y
Positioning precision N ±1 pulse












Product function


Key function
Speed loop, torque loop, position loop, orientation control, current limit, torque limit, motor auto tune, inertia auto tune, deep flux−weakening control, over − voltage control, under − voltage control, motor flying start, droop control, oscillation suppression, random carrier frequency, master follower control, etc.


Speed reference source
Modbus communication, keypad, external digital input, analog input AI1/AI2/AI3, pulse input, simple PLC, PID, CAN/CANopen, PROFIBUS−DP, PROFINET, etc.


Dynamic brake
Brake chopper action voltage: 650 ... 750V.
The brake chopper of products 0.75kW to 110kW can be built−in:
  • 0.75...15kW: brake chopper is built−in as standard.
  • 18.5...110kW: brake chopper is built−in as option.

Communication
Built  in Modbus  RTU communication, the maximum distance up to 500 meters.

Keypad
LED keypad and LCD keypad are available.
The keypad can be used as remote−control box by a net cable.
Common DC bus Full series product support common DC bus directly.
Independent air duct All series product adopts independent duct design.



Protection
Power supply under−voltage, over−current protection, over−voltage protection, auto−tune fault, module protection, heat−sink over-temperature protection, drive overload protection, motor overload protection, peripheral protection, current abnormal detection, output short  circuit to ground protection, EEPROM abnormal detection, temperature sampling disconnection, encoder disconnection, analog input abnormal detection, motor over-temperature, communication fault, hardware overload protection, etc.


Efficiency
At rating condition:
  • 0.75kW to 7.5kW: ≥93%
  • 11kW to 45kW: ≥95%
  • 55kW and higher power class: ≥98%












Environment



Operating site
  • Install vertically in a well−ventilated electrical cabinet. Horizontal or other installation methods are not allowed.
  • The cooling medium is air.
  • Installed in an environment free from direct sunlight, dust, corrosive gases, flammable gases, oil mist, steam, dripping.


Ambient temperature
  • −10 ... +40ºC
  • Derate the output current by 1% for each 1 °C to install the drive in ambient temperature between 40 to 50 °C.
Humidity 5 ... 95%, no condensation is allowed.


Altitude
  • 0 ... 4000 meters
  • Derate the output current by 1% for each 100 meters to install the drive in altitudes between 1000 to 4000 meters.


Vibration
  • 3.5 m/s2, 2 ... 9Hz
  • 10 m/s2, 9 ... 200Hz
  • 15 m/s2, 200 ... 500Hz
Storage temperature −40 ... +70ºC.
 
Terminal Wiring

V9 11kw High Performance Universal Speed AC Drive/VFD/Frequency Inverter

 

Terminal Symbol Function description Technical specifications

Modbus
485+ RS485 positive end Baud rate: 4800/9600/19200/38400/57600/57600bps
Up to 32 units are connected in parallel.
If more than 32 units are used, repeaters are required.
485 - RS485 negative end  
GND Modbus ground terminal  
Keypad CN7 RS485 port of keypad The maximum distance for keypad is 15 m ( network cable)


Digital inputs
+24V +24V 24V±10%, internal isolated with GND Maximum output current: 200mA
PLC Power supply of DI Short to +24V by default
X1 ... X7 Digital inputs 1 ... 7 Input specification: 24VDC  ± 20%, 5mA
Frequency range: 0  1KHz
COM Digital inputs common The interior isolated from GND
Digital  outputs Y1 Open collector output 1 Voltage range: 24V±20%
Maximum output current: 50mA
Y2 Open collector output 2  
COM Y1 and Y2 common The interior isolated from GND



Relay  outputs

RA/RB/RC

Relay output 1
RA-RB: Normally closed RA-RC: Normally open
Contact capacity: 250VAC/1A, 30VDC/1A
RA1/RC1 (≥11kW) Relay output 2 RA1-RC1: Normally open
Contact capacity: 250VAC/1A, 30VDC/1A
RA2/RC2 (≥11kW) Relay output 3 RA2-RC2: Normally open
Contact capacity: 250VAC/1A, 30VDC/1A



Analog inputs
+10V AI reference voltage 10V  ±3%, internal isolated with COM Maximum output current: 10mA
AI1 Analog input 1 −10V...10V: Input impedance 20kQ , max. voltage:  ±15V 0...20mA: Input impedance 500Q , max. current: 30mA
Resolution: 12 bits (0.025%)
Note: AI3 input current 0...20mA is not supported.
AI2 Analog input 2  
AI3 Analog input 3  
GND Analog GND The interior isolated from COM

Analog outputs
AO1 Analog output 1 Select analog voltage or current output by jumper
0 ... 20mA: Output allowable impedance 200 to 500 Ω 0 ... 10V: Output allowable impedance ≥10kΩ
AO2 Analog output 2  
GND Analog ground terminal The interior isolated from COM





Resolver (≥11kW)
1 REF− Resolver signal REF1
2 REF+ Resolver signal REF+
3 SIN+ Resolver signal SIN+
4 SIN− Resolver signal SIN−
5 COS+ Resolver signal COS+
6 PT100 PT100 temperature sensor
7 COM PT100 gnd
8 None  
9 COS− Resolver signal COS−

 

 

Dimension

V9 11kw High Performance Universal Speed AC Drive/VFD/Frequency Inverter



Voltage


Model
Outline and mounting dimensions (mm)
Weight (kg)

W

H

D

W1

H1

T1
Mounting hole
diameter d
















400V
V9−H−4T0.75G/1.5L 118 190 155 105 173 3 5.5 1.5
V9−H−4T1.5G/2.2L
118

190

175

105

173

4

5.5

2.6
V9−H−4T2.2G/3.7L
V9−H−4T3.7G/5.5L
V9−H−4T5.5G/7.5L 155 249 185 136 232 8 5.5 3
V9−H−4T7.5G/11L
V9−H−4T11G/15L 198 299 190 160 283 1.2 6 8
V9−H−4T15G/18.5L
V9−H−4T18.5G/22L 223 348 208 195 335 1.5 6 10
V9−H−4T22G/30L
V9−H−4T30G/37L 264 430 235 230 418 1.5 7 18
V9−H−4T37G/45L
V9−H−4T45G/55L 305 545 270 245 523 1.5 10 35
V9−H−4T55G/75L
V9−H−4T75G/90L
338

580

310

270

560

1.5

10

52
V9−H−4T90G/110L
V9−H−4T110G/132L
V9−H−4T132G/160L 400 917 323 320 890 3.0 12 75
V9−H−4T160G/185L
V9−H−4T185G/200L 540 890 385 370 855 4.0 14 85
V9−H−4T200G/220L
V9−H−4T220G/250L 540 890 416 370 855 4.0 14 85
V9−H−4T250G/280L 700 1010 385 520 977 4.0 14 125
V9−H−4T280G/315L
V9−H−4T315G/355L 700 1010 418.5 520 977 4.0 14 125
V9−H−4T355G/400L 810 1358 425 520 1300 4.0 14 215
V9−H−4T400G/450L
810

1358

425

520

1300

4.0

14

215
V9−H−4T450G/500L
V9−H−4T500G/560L



V9 11kw High Performance Universal Speed AC Drive/VFD/Frequency Inverter

 










 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier