Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
---|---|
Output Type: | Triple |
Principle of Work: | Vector Control Transducer |
Switch Mode: | PWM Control |
Main Circuit Type: | Voltage |
Voltage of Power Supply: | Low Voltage Variable-Frequency Drive |
Suppliers with verified business licenses
1.5kw AC Frequency Inverter for Motor |
1. AC Frequency Inverter for motor
2. Excellent torque control and reliable brake control frequency inverter
3. Approved by ECMG, CE, ABS, TUV, ISO9000
4. Global frequency inverter supplier
With complete applications for water supply, with high efficiency, pressure stable, reliable, simple operation, easy installation, small footprint, low noise, no pollution, low investment, effective advantages. Widely used in:
Power(KW) |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
75 |
|
Motor Power(KW) |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
75 |
|
Output |
Voltage(V) |
Three-phase 0V to rated input voltage |
||||||||||||||
Rate current(A) |
2.5 |
3.8 |
5.5 |
9 |
13 |
17 |
24 |
30 |
39 |
45 |
60 |
75 |
91 |
112 |
150 |
|
Overload capacity |
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) |
|||||||||||||||
Input |
Rated voltage/frequency |
Three-phase 380V/480V; 50Hz/60Hz |
||||||||||||||
Allowable voltage range |
323V ~ 528V; Voltage unbalancedness ≤ 3%; allowable frequency fluctuation: ± 5% |
|||||||||||||||
Rate current(A) |
3.5 |
6.2 |
9.2 |
14.9 |
21.5 |
27.9 |
39 |
50.3 |
60 |
69.3 |
86 |
104 |
124 |
150 |
201 |
|
Braking unit |
Built-in as standard |
External braking unit needed |
||||||||||||||
Protection class |
IP20 |
|||||||||||||||
Cooling mode |
Self-cooling |
Forced air convection cooling |
Power(KW) |
90 |
110 |
132 |
160 |
200 |
220 |
280 |
315 |
355 |
400 |
... |
... |
... |
... |
... |
|
Motor Power(KW) |
90 |
110 |
132 |
160 |
200 |
220 |
280 |
315 |
355 |
400 |
||||||
Output |
Voltage(V) |
Three-phase 0V to rated input voltage |
||||||||||||||
Rate current(A) |
176 |
210 |
253 |
304 |
377 |
415 |
520 |
585 |
650 |
740 |
||||||
Overload capacity |
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) |
|||||||||||||||
Input |
Rated voltage/frequency |
Three-phase 380V/480V; 50Hz/60Hz |
||||||||||||||
Allowable voltage range |
323V ~ 528V; Voltage unbalancedness ≤ 3%; allowable frequency fluctuation: ± 5% |
|||||||||||||||
Rate current(A) |
160* |
196* |
232* |
282* |
352* |
385* |
491* |
552* |
624* |
704* |
||||||
Braking unit |
External braking unit needed |
|||||||||||||||
Protection class |
IP20 |
|||||||||||||||
Cooling mode |
Forced air convection cooling |
Power(KW) |
90 |
110 |
132 |
160 |
200 |
220 |
280 |
315 |
355 |
400 |
... |
... |
... |
... |
... |
|
Motor Power(KW) |
90 |
110 |
132 |
160 |
200 |
220 |
280 |
315 |
355 |
400 |
||||||
Output |
Voltage(V) |
Three-phase 0V to rated input voltage |
||||||||||||||
Rate current(A) |
176 |
210 |
253 |
304 |
377 |
415 |
520 |
585 |
650 |
740 |
||||||
Overload capacity |
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) |
|||||||||||||||
Input |
Rated voltage/frequency |
Three-phase 380V/480V; 50Hz/60Hz |
||||||||||||||
Allowable voltage range |
323V ~ 528V; Voltage unbalancedness ≤ 3%; allowable frequency fluctuation: ± 5% |
|||||||||||||||
Rate current(A) |
160* |
196* |
232* |
282* |
352* |
385* |
491* |
552* |
624* |
704* |
||||||
Braking unit |
External braking unit needed |
|||||||||||||||
Protection class |
IP20 |
|||||||||||||||
Cooling mode |
Forced air convection cooling |
Suppliers with verified business licenses